| Features |
- Compact size and low
5-mm profile.
- Low power consumption (140mW for single-side stable,
100 to 300mW for latching type).
- Low thermo electromotive force.
- Low magnetic interference enables high-density mounting.
- Single-and double-winding latching types also available.
- UL and CAS approval. |
| Contact resistance(1) |
100mΩ Max. |
| Operate time(1) |
single-side stable type:
3ms Max. |
| latching type: 3ms Max. |
| Release time(1) |
single-side stable type:
2 ms Max |
| latching type: 3ms Max. |
| Bounce time |
operate: approx 0.5ms |
| release: approx 0.5ms |
| set/reset: approx 0.5ms |
| Min. set/reset signal width |
latching type: 5ms min. |
| Insulation resistance(1) |
1000MΩMin.(DC 500V)
Between set and reset coil: 100MΩ(DC125V) |
| Dielectric strength(1) |
Between coil and contacts:
AC 1000V, 50/60Hz 1 min. |
| Between contact of different
polarity: AC 1000V, 50/60Hz 1 min. |
| Between contact of same
polarity: AC 750V, 50/60Hz 1 min. |
Between set and reset coil:
AC 125V, 50/60Hz 1 min.
(double-winding latching) |
| Surge withstand voltage |
Between contact of same
polarity: AC 1500V(10×160μs)
(conforms to FCC part 68) |
| Vibration resistance |
Operating extremes |
10~55Hz, double amplitude 5mm |
| Damage limits |
10~55Hz, double amplitude 3mm |
| Shock resistance |
Operating extremes |
500 ㎨ |
| Damage limits |
1000 ㎨ |
| Life expectancy |
Mechanical |
100,000,000 operations
(frequency 36,000 operations/hr) |
| Electrical |
200,000 operations
(frequency 1,800 operations/hr) |
| Operating ambient temperature |
-40 ~ +70℃(no freezing) |
| Weight |
Approx. 1.5g |