1. Features
● 16A switching capabilities
● Sealed & Unselaed types available
● 1 &2 pole configurations
● 5KV / 10mm dielectric strength
● Low height 15.7mm
● Sealed and unsealed type available
● High temperature 105 degree
● High Inrush TV-5 80A
● High Sensitive 0.25W
2. CONTACT DATA
1A, IB, 1C
2A, 2B, 2C
Contact Form
Silver Alloy
Contact Material
Max. 12A/16A
Max 8A
Contact current
440VAC / 125VDC
Switching Voltage
440VAC / 125VDC
Contact capacity
3,000VA
4,000VA
2,000VA
Contact resistance
50m ohm
Electrical Life
100,000operations
(At 30 operations / minute)
Mechanical Life
10,000,000 operations
3. OPERATION CONDITION
Insulation Resistance
100M Ω Min. at 500VDC
Dielectric Strangth
Open Contacts
1,000VAC (For one minute)
Contacts
and Coil
5,000VAC (For one minute)
Contact sets
2,500VAC (For one minute)
Operate time
7ms
Release Time
3ms
Temperature Range
-40℃ ~ 70℃
Shock Resistance
100m/s2
Vibration Resistance
10 ~ 150Hz 10g / 5g
Humidity
35 ~ 85%
Dimension
29 x 12.7 x 15.7mm
Weight
Approx. 13.5g
Construction
Sealed and unsealed
4.COIL DATA
Coil Consumption
0.4W, 0.25W
Coil Voltage
5 ~ 110 VDC
Coil Resistance
See below table
5. TABLE
DC Coil
( at 20℃ )
Nominal
Voltage
VDC>
Pick-up
Voltage
VDC
Drop-out
Voltage
VDC
Coil
Current
mA
Coil
Resistance
Ω
Pick-up
Voltage
VDC
Drop-out
Voltage
VDC
Coil
Current
mA
Coil
Resistance
ohm
Standard Coil, 0.4W
Sensitive Coil, 0.25W
5
3.50
0.5
80.0
62±10%
3.75
0.5
50.0
100±10%
6
4.20
0.6
66.7
90±10%
4.50
0.6
41.7
144±10%
12
8.40
1.2
33.3
360±10%
9.00
1.2
20.8
576±10%
24
16.80
2.4
16.7
1,440±10%
18.00
2.4
10.4
2,304±10%
48
33.60
4.8
8.3
5,760±10%
36.00
4.8
5.4
9,216±10%
60
42.00
6.0
8.0
7,500±10%
45.00
6.0
4.7
12,857±10%
100
77.00
11.0
4.3
25,200±10%
AC Coil
( at 20℃ )
Nominal
Voltage
VDC
Pick-up
voltage
VDC
Drop-out
voltag
VDC
Coil
resistance
mA
Coil
Resistance
ohm
24
18.00
3.60
31.6
350±10%
115
86.30
17.30
6.6
8,100±10%
230
172.50
34.50
3.2
32,500±10%
6. SAFETY STANDARD
Standard
File Number
Remarks
UL
E222977
VDE