제품소개 > 릴레이 > PART 4 > RH
1. Features
=30A switching capabilities
PCB & QC terminals
Heavy load up to 7,200VA
Open, sealed & unsealed type available
Class B, Class F insulation available
4K dielectric coil to contact
Size (mm) :
27.5 x 32.4 x 27.8
2. CONTACT DATA
Contact Form
1A
1B
1C(NO)
1C(NC)
Initial contact resistance
50m ohm at 1A 24VDC
Max. Switching Capacity
7200VA/560W
3600VA/280W
4800VA/560W
2400VA/280W
Max. Switching Voltage
277VAC / 28VDC
Max. Switching Current
30A
15A
20A
10A
Contact Rating
30A 240VAC
20A 28VDC
15A 240VAC
10A 28VDC
20A 240VAC
20A 28VDC
10A 240VAC
10A 28VDC
UL/CUR rating
30A 277VAC
20A 28VDC
2HP 250VAC
1HP 125VAC
15A 277VAC
20A 277VAC
20A 28VDC
2HP 250VAC
1HP 125VAC
10A 277VAC
10A 28VDC
1/4HP 250VAC
1/2HP 125VAC
Life Expectancy
Electrical
100,000 Operations (at 30 ops a minute)
Mechanical
10,000,000 Operations
3. OPERATION CONDITION
Insulation Resistance
1000MΩ min (at 500VDC)
Dielectric Strength
Between open Contacts
1,500VAC (For one minute)
Between coil & Contacts
2,500VAC (For one minute)
Operate time(At nomi. Volt.)
15ms
Release Time(At nomi. Volt.)
10ms
Ambient Temperature
Class B
DC : - 55 to 85°C AC : - 55 to 60°C
Class F
DC : - 55 to 105°C AC : - 55 to 85°C
Shock Resistance
Functional
98 m/s2
Destructive
980 m/s2
Vibration resistance
DA: 1.5mm, 10 - 55Hz,
Humidity
98%, +40°C
Weight
Approx 36g
4. COIL PARAMETER
Nominal
Voltage(VDC)
Max. Operate
Voltage VDC
Min. Release
Voltage VDC
Coil Resistance
ohm
5
3.75
0.5
27±10%
6
4.5
0.6
40±10%
9
6.75
0.9
97±10%
12
9.00
1.2
155±10%
15
11.25
1.5
256±10%
18
13.50
1.8
380±10%
24
18.00
2.4
660±10%
48
36.00
4.8
2,560±10%
70
52.50
7.0
5,500±10%
110
82.50
11
13,450±10%
Nominal
Voltage(VDC)
Max. Operate
Voltage VDC
Min. Release
Voltage VDC
Coil Resistance
ohm
12
9.6
2.4
25±10%
24
19.2
4.8
100±10%
120
96.0
24.0
2,500±10%
208
166.4
41
11,000±10%
220/240
192
48
13,490±10%
277
220
54
15,000±10%