| 1. ORDERING CODE |
|
| RK-12 E |
RK |
1 |
Relay Model |
| 12 |
2 |
Coil voltage : 6V, 12V, 24V |
| E |
3 |
Nil :
Quick connect type with bracket |
| E : Quick connect type without bracket |
| 2. COIL DATA |
|
| Nominal Voltage |
6 |
12 |
24 |
1.44W |
| Coil Resistance(Ω±10%) at 20℃ |
25 |
100 |
400 |
| Rated Curren(mA) |
240 |
120 |
60 |
| Max Operate Voltage(VDC) |
3.9 |
7.8 |
15.6 |
| Min Release Voltage(VDC) |
0.3 |
0.6 |
1.2 |
| Max ApplicableVoltage |
70℃ /130%,23℃ /170% |
| 3. COIL PARAMETER |
|
| Contact Form |
1 Form A |
| Contact Material |
Silver Alloy |
| Load |
Resistive load(COSФ=1) |
| Contact Ratings |
30A 14VDC
|
| 15A 28VDC |
| Max Switching Voltage |
14VDC |
| Max Switching Current |
30A |
| Max Switching Power |
420W |
| Contact Resistance |
100mΩMax |
at 6VDC 1A |
| Life Expectancy |
Electrical : 100,000 Operations(at30Operations/minute) |
| Mechanical : 10,000,000 Operations |
| 4. GENERAL DATA |
|
| Insulation Resistance |
100MΩMin at 500VDC |
| Dielectric Strength Between Open Contacts |
500VAC(for one minute) |
| Between Contacts and coil |
500VAC(for one minute) |
| Operate Time |
15ms |
| Release Time |
8ms |
| Temperature Range |
-40℃to+85℃ |
| Shock Resistance |
Operating Extremes기능적: 10G |
| Damage Limits파괴적: 100G |
| Vibration Resistance |
10-55Hz, 1.5mm |
| Max. switching frequency |
Mechanical:18,000operations/hr |
| Electrical:1,800operations/hr |
| Humidity |
45-85% |
| Weight |
Approx 28g |