제품소개 > 릴레이 > PART 4 > BC3
 
1. Features

● DIL Pitch Terminals .High Sensitivity.
● Dielectric 1000VAC.
● Fully sealed (immer1sion clearable).
● High Reliability bifurcated Contact.
● Application for
Telecommunication Equipment.
Office Equipment, Security Alarm Systems.
Measuring instruments.
Medical Monitoring Equipment. etc.

2. CONTACT DATA
Contact Arrangement
2C(Bifurcated Crossbar)
Contact Material
Ag + Au
AgNi + Au
Contact Rating (resistive)
1A/24VDC; 0.5A/120VAC
1A 120VAC, 2A 24VDC
Rated load (Res. Load)
0.01mA/10mV(Reference Value)
Max. Switching Current
2A
Max. Switching Power
60W 120VA
Max. Switching Voltage
60VDC 240VAC

Contact Resistance or
Voltage drop

£100mΩ
Operation life Electrical
1×105 at 30 Operations per minute
Mechanical 107
CAUTION : Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in law level applications
3. COIL PARAMETER

Coil voltage
(VDC)

Coil resistance (Ω±10%)

Pickup     voltage(max)
(VDC)

release voltage(min)
(VDC)

Applicable
Voltage(Max)
(VDC)

0.15W 0.2W 0.36W 0.45W
3 60 45 25

20

2.25 0.3 3.9
5 167 125 70 56 3.75 0.5 6.5
6 240 180 100 80 4.5 0.6 7.8
9 540 405 220 180 6.75 0.9 11.7
12 960 720 400 320 9 1.2 15.6
24   2800 1600 1280 18 2.4 31.2
48     6400±15% 5100±15% 36 4.8 62.4
 

CAUTION : 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the                      relay.
                   2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.

 
4. OPERATION CONDITION

100MΩ Min at 500VDC

Dielectric
Strength

Open Contacts
500 / 750 VAC ( For one minute / second)
Contact and Coil 1000 / 1250 VAC (For one minute / second)
Operate Time
6ms
Release Time
4ms
Temperature Range
-30℃ to + 70 ℃
Shock Resistance Operating Extremes
10G
Damage Limits 50G

Vibration resistance

10~55Hz Double amplitude 1.5mm
Humidity
40 – 85%
Weight 5g